Datasheet

5
Agilent 82357B USB/GPIB Interface Converter
Features
Fast and easy connection to GPIB
instruments
Uses standard USB and IEEE-488
interfaces
Maximum GPIB transfer rate of
1.15 MB/s
Parallel polling capability
Best for
Easiest GPIB connectivity
Notebook computer GPIB
connection
Connect GPIB instruments
quickly and easily to your
computer’s USB port
The Agilent 82357B USB/GPIB
interface provides a direct connection
from the USB port on your desktop
and laptop computers to GPIB instru-
ments. Once the software is loaded,
your computer automatically detects
the 82357B when it is connected to
the USB port of the computer.
The 82357B is a plug-and-play device.
It is also hot-pluggable, making it
easy to connect and disconnect
without having to shut down the
computer. No external power supplies
are necessary.
The 82357B USB/GPIB interface
implements USB 1.1 (12 Mbits/s)
and is compatible with USB 2.0. The
82357B USB/GPIB interface uses a
thin, flexible, high-quality USB cable
that is USB 2.0-compliant. The USB
cable is shielded, and the connector
is specified to 1,500 insertions, ensur-
ing a durable connection and reliable
data transfer.
82357B technical specifications
General requirements
Minimum system
requirements
Refer to page 4 for requirements in using the Agilent
IO Libraries software (included with the connectivity
product)
Supported standards Supports USB 2.0 high speed and full speed
Standard USB endpoints supported
IEEE-488.1 and IEEE-488.2 compatible
SICL and VISA 2.2
Unsupported GPIB modes of
operation
• Pass Control
Non-System Controller mode
General characteristics
Power USB bus-powered device, +5 V, 500 mA (maximum),
200 mA (typical)
Maximum data rate (GPIB) 1.15 MB/s
Connectors Standard 24-pin IEEE-488
Standard USB A
USB hubs Self-powered hubs
Parallel polling A single parallel poll can easily check up to eight
individual devices at once, corresponding to the
number of data lines on the GPIB
Cable 2.5 meters, shielded, connector rated for 1,500
insertions
LED indicators READY, ACCESS, FAIL
Maximum instrument
connection
14 instruments—daisy chain via GPIB. A maximum of
4 converters can be connected to the PC.
Configuration Plug-and-play
Warranty 1 year
EMC and safety IEC 61010-1: 2001/EN 61010-1: 2001
USA: UL61010-1: 2004
Canada: CSA C22.2 No. 61010-1: 2004
Dimensions
Length, width, and height 105 mm (L) x 64 mm (W) x 30 mm (H) (including
connectors)
Weight 215 grams
Environmental specifications
Operating environment 0 °C to 55 °C
Operating humidity Up to 90% at 40 °C non-condensing
Storage environment –40 °C to 70 °C
Storage humidity Up to 90% at 65 °C non-condensing
Ordering information
Includes Agilent IO Libraries Suite and VISA/SICL programming
manuals on CD-ROM
Accessories None
Boosting performance with
simplest connectivity