Manual
3
SR-750_AFM_E
 COOP2of5
Quiet zone scale factor (4-11)
.......Set the quiet zone scale factor.
 CODE39(Trioptic CODE39)
Trioptic CODE39......................Check this to allow reading of Trioptic CODE39.
3 Details of Japanese Pharmaceutical 
Code Quality Verification Function
Symbology for code quality verification
•GS1-128
• GS1 DataBar Limited
• GS1 DataBar Stacked
• CC-A (GS1 DataBar Limited)
• CC-A (GS1 DataBar Stacked) 
Settings of the Japanese Pharmaceutical Code quality 
verification function
To use the Japanese Pharmaceutical Code quality verification function, you need 
to enable the verification settings.
(1) Setting using the AutoID Network Navigator
Press the "Code quality verification" button on the "Operation" tab in the 
Settings view, and then check "Japanese Pharmaceuticals". In addition, select 
the code to be verified.
Name of verification function Explanation
Japanese Pharmaceutical Code quality 
verification
Function for evaluating the print quality of codes on 
pharmaceuticals, recommended by the Safety 
Division of Pharmaceutical and Food Safety Bureau 
and the Economic Affairs Division of Health Policy 
Bureau under the Ministry of Health, Labour and 
Welfare.
It makes reference to ISO/IEC15415 and ISO/
IEC15416.
(2) Setting using the setup commands
Send commands that enable the Japanese Pharmaceutical Code quality 
verification function.
For configuration commands, refer to  "5 Modified and Added Configuration 
Commands" (Page 6).
Point
When the Code quality verification function is enabled, the decode 
time becomes longer than when it is disabled.
Perform calibration after enabling the Code quality verification 
function or set the decode timeout period required for reading.
Use the tact measurement test mode to confirm that there is no 
problem with the reading time for operation.
 Other settings, functions, and precautions regarding the 
code quality verification
The following settings, functions, and precautions are similar to those of ISO/
IEC15415.
For details, refer to  "3-11 Code quality verification function in SR-750 Series 
User's Manual".
• Append Code quality verification result data
• For the data format with data appended, refer to  "Other Modifications" (Page 
7).
• Code quality verification function Evaluation standard
• Functions that can use evaluation results of the Code quality verification function
• Notes when using the Code quality verification function
Description of verification items 
Japanese Pharmaceutical Code quality verification 
(GS1 DataBar Limited, GS1 DataBar Stacked, GS1-128)
Decode success/failure DEC (Decode)
Description Evaluates whether decoding is possible or not.
-
Calculation 
formula
-
Criterion
A : Success
F : Failure
Number of edges EDGE (EdgeDetermination)
Description
Determines whether the read number of edges 
is equal to the assumed number of edges.
-
Calculation 
formula
-
Criterion
A:Match
F:Mismatch
Symbol contrast SC (Symbol Contrast)
Description
Evaluates the difference between the 
maximum brightness value (Rmax) and 
minimum brightness value (Rmin) in the code 
area.
-
Calculation 
formula
SC = Rmax – Rmin
Criterion
A:SC ≥ 70 %
B:SC ≥ 55 %
C:SC ≥ 40 %
D:SC ≥ 20 %
F:SC < 20 %
Minimum Reflectance
MINR
(Minimum Reflectance)
Description
Minimum reflectance among scanned 
waveforms
-
Calculation 
formula
-
Criterion
A:Rmin ≤ 0.5 Rmax
F : Rmin > 0.5 Rmax