6. Install the new relay circuit board in the SL-R11 and tighten the screws. (Recommended tight-
ening torque is 0.6 N•m)
7. Attach the relay output terminal removed in Step 4 to the new replacement relay board
according to the instructions in section 4-2-1 “How to replace the relay output terminal block
(4-2)”.
8. Refer to “Chapter 5. Checklist” ( page 5-1) and check the operation.
WARNING
•A high voltage is generated in the FSD output and AUX output terminals, so
before beginning the replacement work, turn off the power to the SL-C Series
and SL-R11 as well as the power of the devices connected to the FSD output
and AUX output terminals. Leaving the power on could result in electric shock.
When the relay needs to be replaced, replace it with the replacement relay circuit
board (OP-42372) provided by KEYENCE. Do not use parts from another manu-
facturer. Using other parts could cause the SL-C to malfunction, and a serious
accident causing a serious injury or death.