2-6 BL-U1 Connections and Wiring
Installation
2
Wiring OK/NG output
A signal indicating whether the BL/SR/RF Series device was able to make a reading is output
when checking the OK/NG output from a comparison of preset data.
This is open connector output.
Input/output circuit diagram
Load
Load
+
* Rated load: 30V DC (100mA) max.
COM OK NG
+
+
Input circuit diagram
Internal circuit
Internal circuit
Output circuit diagram
TIM
+
Load
COM
OK/NG