Instruction Manual

2-28
Installation
2
2-6 BL-U1 Connections and Wiring
Installing and Wiring the Input and Output Jacks
* These appear in this order from left to right on the terminal.
Use M3.0 screws for the terminal.
The wiring should use crimp contacts as shown below.
Wiring the trigger input
The trigger input is used to cause a BL/SR/RF Series device to begin reading.
The trigger input interval is on when 8.5 to 30 V DC is input.
The BL-U1 sensor power source can be used as the input power source.
Symbol Explanation Signal direction
TIM Trigger input
Input
Input
+12 V OUT-
Sensor power source + side (+12 V DC, 300 mA) Output
Sensor power source + side (0 V) Output
COM OK/NG output common -
OK OK output Output
NG NG output Output
SDA RS-422A data sending + side / RS-485 + side
Output/ input-
output
SDB RS-422A data sending - side / RS-485 - side
Output/ input-
output
SG Signal ground -
RDA RS-422A data reception + side Input
RDB RS-422A data reception - side Input
TIM
Trigger input Sensor power source
(12 V DC, 300 mA)
OK/NG output RS-422A/RS-485
+12V OUT- COM OK NG SDA SDB SG RDA PDB
Round type
6.0 mm max.
Fork type
6.0 mm max.
+
+
Contact or
non-contact
8.5 to 30V DC
TIM +12V OUT–