2-6 BL-U1 Connections and Wiring
Installing and Wiring the Input and Output Jacks
* These appear in this order from left to right on the terminal.
• Use M3.0 screws for the terminal.
• The wiring should use crimp contacts as shown below.
Wiring the trigger input
The trigger input is used to cause a BL/SR/RF Series device to begin reading.
The trigger input interval is on when 8.5 to 30 V DC is input.
The BL-U1 sensor power source can be used as the input power source.
Symbol Explanation Signal direction
TIM Trigger input
Input
Input
+12 V OUT-
Sensor power source + side (+12 V DC, 300 mA) Output
Sensor power source + side (0 V) Output
COM OK/NG output common -
OK OK output Output
NG NG output Output
SDA RS-422A data sending + side / RS-485 + side
Output/ input-
output
SDB RS-422A data sending - side / RS-485 - side
Output/ input-
output
SG Signal ground -
RDA RS-422A data reception + side Input
RDB RS-422A data reception - side Input
TIM
Trigger input Sensor power source
(12 V DC, 300 mA)
OK/NG output RS-422A/RS-485
+12V OUT- COM OK NG SDA SDB SG RDA PDB
Round type
6.0 mm max.
Fork type
6.0 mm max.
+
+
Contact or
non-contact
8.5 to 30V DC