Instruction Manual

7-16
PLC Link
7
7-3 Settings
Mitsubishi MELSEC Series Settings
N-410 Settings
A1SJ71UC24-R2/PRF
AJ71UC24
AJ71QC24(N/-R2), A1SJ71QC24(N/-R2)
Item Specification
PLC type selection Mitsubishi MELSEC Series
Station number 0
Baud rate 9600 bit/s
Data bits 8 bit
Parity Odd
Stop bit length 1 bit
Item Specification
Mode settings 4 (Format 4 protocol mode)
Write during RUN Yes
Baud rate 9600 bit/s
Data bits 8 bit
Parity Odd (o)
Stop bit length 1 bit
Checksum Yes
Item Specification
Station number setting 00
Mode settings 4 (Format 4 protocol mode)
Main channel settings RS-232C
Data bits 8 bit
Baud rate 9600 bit/s
Parity Odd (o)
Stop bit length 1 bit
Checksum Yes
Write during RUN Yes
Calculator link/ Multi-drop
selection
Calculator link
Item Specification
Station number setting 00
Mode settings 4 (Proprietary protocol mode / ASCII mode / Format 4)
Operation settings Independent operation
Data bits 8 bit
Parity Odd (o)
Stop bit length 1 bit
Checksum Yes
Write during RUN Yes
Settings changeable Yes
Transmission speed 9600 bit/s