Instruction Manual

6-18
Serial Communication
6
6-5 Setting Commands for the N-410 Series
ID settings
RS-232C settings
Function Command sent Response Explanation
Register ID numbers
(register one device at a
time)
Change WIDmmn OK mm= 01 to 31: ID number
n = 0: Do not register anything
1: Register
Confirm RIDmm mmn
ID number serial registration
(All ID numbers up to the
specified number will be
registered)
Change
WIDMAXmm
OK
mm= 01 to 31: ID number
*In a response, if mm = 99, no serial
numbers will be recorded.
Confirm
RIDMAXm
m
MAXmm
ID number batch registration
Change
WIDAnnn...n
OK n = 0: Do not register anything
1: Register
*n is ID numbers between from 1 to 31
in sequence
Confirm RIDA Annn...n
Register slave type
Change WTPmmn OK
mm = 01 to 31
n = 0: Nothing
1: N48+BL(SR)
2: N48+RF
3: NX+BL(SR)
4: NX+RF
Confirm RTPmm mmn
Batch register slave type
Change
WTPAnnn...n
OK n = 0: Do not register anything
1: Register
*n is ID numbers between from 1 to 31
in sequence
Confirm RTPA Annn...n
Function Command sent Response Explanation
Baud rate settings
Change WP35n OK
n = 9: 115200 bit/s
8: 57600 bit/s
7: 38400 bit/s
5: 19200 bit/s
4: 9600 bit/s
Confirm RP35 35n
Data bits settings
Change WP30n OK
n = 0: 7 bit
1: 8 bit
Confirm RP30 30n
Parity type settings
Change WP32n OK n = 0: None
1: Even
2: Odd
Confirm RP32 32n
Stop bit length settings
Change WP33n OK
n = 0: 1 bit
1: 2 bit
Confirm RP33 33n
RTS/CTS protocol settings
Change WP22n OK
n = 0: Do not activate
1: Activate
Confirm RP22 22n