Instruction Manual
6-16
Serial Communication
6
6-5 Setting Commands for the N-410 Series
Trigger input settings (only available when using multi-head mode)
Send the following commands for trigger input on/off command character settings.
(Example) Changing the trigger input on command to S or S
S
WP5653 *S = 53h
Function Command sent Response Explanation
Measurement method
settings
(Trigger mode)
Change WP05n OK
n = 0: Synchronize levels
1: One-shot synchronization
Confirm RP05 05n
Settings for one-shot
synchronization measurement
Change WP42nnn OK
nnn = 001 to 255
(units: 100 ms)
Confirm RP42 42nnn
Settings for trigger input at
input time
Change WP04n OK
n = 0: 2 ms
1: 10 ms
Confirm RP04 04n
Trigger input polarity settings
Change WP03n OK
n = 0: Normal open point
1: Normal close point
Confirm RP03 03n
Trigger input on command
character settings
Change WP56hhh... OK hhh... = Trigger input on command
(Up to 8 characters)
* Settings are specified in hexadecimal
(up to 16 characters).
Confirm RP56 56hhh...
Trigger input off command
character settings
Change WP57hhh... OK hhh... = Trigger input off command
(Up to 8 characters)
* Settings are specified in hexadecimal
(up to 16 characters).
Confirm RP57 57hhh...
Reference
CR
STX
ETX