Instruction Manual

Serial Communication
6
6-13
6-5
Setting Commands for the N-410 Series
Settings for the N-410 Series can be changed with commands.
Setting Command Communication Procedure
This section describes the procedure for setting command communication.
1 Send the setting mode command (SSET) to the N-410 Series.
The 410-N Series shifts to the setting mode and the display of the 7-segment is changed to [55].
If the command is successfully executed: ... The N-410 Series sends back "OK".
2 Send a command to change or confirm the setting.
When the setting change command is sent:
If the command is successfully executed: ... The N-410 Series sends back "OK".
If a setting error occurs:........The BL-1300 Series sends back "ERR**" (**: Error code).
When the setting confirmation command is sent:
If the command is successfully executed: ...The N-410 Series sends back the current setting data.
If an error occurs:.......The N-410 Series sends back "ERR**" (**: Error code).
3 To save the settings in the EEP-ROM, send the save command "SAVE".
Once the settings are saved in the EEP-ROM, the N-410 Series will start with the saved settings
the next time it is turned on.
If the command is successfully executed: ... The N-410 Series sends back "OK".
If an error occurs: ...... The N-410 Series sends back "ERR**" (**: Error code).
4 Send the command (SEND) to return the N-410 Series to run mode.
If the command is successfully executed: ... The N-410 Series sends back "OK".
If an incorrect command is sent: ....... The N-410 Series sends back "ERR**".