Instruction Manual
6-12
Serial Communication
6
6-4 Direct Control Command of the N-410 Series
The polling command in manual polling
Sends the polling command to a specified ID number in manual polling and obtains data from
the head that has the specified ID number.
Command sent : %Pmm (mm = 01 to 31: ID number)
Response : %Pmm - nnnn result data (nnnn = the number of characters in data)
* Results data includes read data and read error codes.
%Pmm - 0005e (e: No data)
Command sends procedure in manual polling
Sends the trigger input ON command (LON) to a BL Series device that has the ID number 3
and obtains the results data (KEYENCE) by sending the manual polling command.
Shifting in or out of the setting mode
Shift to the setting mode Command sent : SSET
Response : OK
Quit the setting mode Command sent : SEND
Response : OK
Operation Command/Response
(1) Send the trigger input on %T03-LON
(2) Respond to (1) %T03-OK
(3) Send the polling command %P03
(4)-1 With results data %P03-0011KEYENCE
(4)-2 Without results data %P03-0005e
Reference
CR
CR
CR
CR
CR