Owner's manual
Table Of Contents
- N-400 User's Manual
- Software License Agreement
- Safety Precautions
- Warnings and Cautions Specific to the N-400
- List of Package Contents
- Contents
- Chapter 1 Overview of the N-400
- Chapter 2 Installation Procedure
- Chapter 3 N-400 Setup Procedure
- Chapter 4 Multi-Drop Link Mode Control Procedure
- Chapter 5 Multi-Head Mode Control Procedure
- Chapter 6 PLC Link
- Appendices
- WARRANTIES AND DISCLAIMERS:

79
Chapter 4 Multi-Drop Link Mode Control Procedure
4
■ PROTOCOL SETUP
Handshaking
protocol 1
Function
Command
Response
Description
Change
WP07n
OK
n = 0: No handshaking
n = 1: Use protocol
Confirm RP07 07n
Handshaking
protocol 2
Change OK
n = 0: PASS/RTRY
protocol
n = 1: ACK/NAK protocolRP08Confirm
08n
Header
Change
WP08n
WP51hhh...
OK
hhh... = Header (up to
five characters)
* To set a header, use
HEX (hexadecimal)
codes.
* hhh... = FF: Header is
not set.
Confirm RP51
51hhh...
Delimiter
Change
WP52hhh...
OK
hhh... = Delimiter (up to
five characters)
* To set a delimiter, use
HEX (hexadecimal)
codes.
* hhh... = FF: Delimiter is
not set.
Confirm
R39 39n
Adding
checksum
Change WP39n OK
n = 0: Do not add
n = 1: Add
Confirm
RP39 39n
*To set details of the
protocol, use
handshaking protocol 2.
Error code
00, 02,
05, 07,
14
00, 02,
05, 10,
12, 14
00, 02,
05, 07,
14