Owner's manual

Table Of Contents
Chapter 4 Multi-Drop Link Mode Control Procedure
78
4
TRIGGER INPUT SETUP (Effective in multi-head scan mode only)
To set the characters of the trigger ON/OFF commands, use the following com-
mand format:
Example: To change the trigger ON command to “[CR]” or “[STX]S[ETX]”.
WP5653 * S = 53h
S
Tips
Trigger
input signal
type
Function
Command
Response
Description
Change
WP05n
OK
n = 0: Level
n = 1: One-shot
Confirm RP05 05n
One-shot
input time
Change
WP42nnn
OK
nnn = 001 to 255
(Units: 100 ms)
RP42Confirm 42nnn
Trigger
input
time
Change WP04n
OK
n = 0: 2 ms
n = 1: 10 ms
Confirm
RP04
04n
State of
trigger input
Change
WP03n
OK
n = 0: Normally open
n = 1: Normally closed
Confirm RP03 03n
Characters of
trigger ON
command
Change
WP56hhh...
OK hhh... =
Trigger ON command
(up to eight characters)
* To set this command,
use HEX (hexadecimal)
codes.
Confirm RP56
56hhh...
Characters of
trigger OFF
command
Change
WP57hhh..
OK
hhh... = Trigger OFF
command (up to eight
characters)
* To set this command,
use HEX (hexadecimal)
codes.
Confirm 57hhh..
Error code
00, 02,
05, 07,
14
00, 02,
05, 07,
09, 14
00, 02,
05, 07,
14
00, 02,
05, 06,
11, 14
00, 02,
05, 06,
11, 14