137
Appendices
Appendices
Appendix H Setup Parameter List
HOST MODE
TRIGGER SETUP (Effective in multi-head mode only)
PROTOCOL SETUP
Mode ❑ Multi-drop link mode
❑ Multi-head mode Interference suppression ❑ Disable
❑ Enable
Trigger ON time for ( )
interference suppression * 10 ms to 2550 ms
Reading mode
❑ Single label
❑ Multi label 1
❑ Multi label 2
Data-send timing ❑ After reading
❑ At trigger OFF
Read error code ( )
* Up to eight characters
Trigger input signal type ❑ Level ❑ One-shot
One-shot input time ( ) * 100 ms to 25.5 s
Input time ❑ 2 ms ❑ 10 ms
State ❑ Normally-open ❑ Normally-closed
Trigger ON command ( ) * Up to eight characters
Trigger OFF command ( ) * Up to eight characters
PLC link ❑ Disable Handshaking ❑ No handshaking ❑ PASS/RTRY
❑ ACK/NAK
Header
❑ None ❑ STX ❑ ESC
❑ Custom ( ) * Up to five characters
Delimiter
❑ CR ❑ CR + LF ❑ ETX
❑ Custom ( ) * Up to five characters
Add ID ❑ Do not add ❑ Add
Checksum ❑ Do not add ❑ Add
❑ Enable PLC model name ❑ SYSMAC-C ❑ MELSEC-A
❑ KV
PLC trigger area ❑ Disable ❑ Enable
DM head address ( ) 00 * 0000 to 9900
PLC station/ ( ) * 000 to 255
unit number
File register ❑ Disable ❑ Enable
File register ( ) * 000 to 255
block number