User Manual

4
Settings for Advanced Functions
4-4
- Digital Laser Sensor LV-N10 Series User's Manual -
4-2
Basic Settings
The detection stability will increase when the response time is delayed.
You can select from the following 6 power modes.
The response time slows down in the order of hSP, FinE, turb, Supr, ULtr, MEGA.
* Cannot be selected when the LV-S31/S62/S63 sensor head is connected.
You can select from the following 3 sensitivity setting methods.
* Refer to the following 2 pages for details.
Power Modes
Refer to page 4-2 "Basic Settings" for setting methods.
Display Power mode name Response time
hSP
*
HIGH SPEED mode 80 øs
FinE FINE mode 250 øs
turb TURBO mode (Default) 500 øs
SuPr SUPER mode 1 ms
ULtr ULTRA mode 4 ms
MEGA MEGA mode 16 ms
Sensitivity Setting
Refer to page 4-2 "Basic Settings" for setting methods.
Display Sensitivity setting method
Reference
page
Std Normal sensitivity setting (without correction) (Default) 3-5 to 3-15
SEtP Percentage calibration 4-5
0SEt Zero shift calibration 4-6