User Manual

4-1 List of Settings
4
Settings for Advanced Functions
4-3
- Digital Laser Sensor LV-N10 Series User's Manual -
2-Output ( )
*14
(page 4-33)
*1 hsp cannot be selected when LV-S31/S62/S63 is connected.
*2 You can press the button to set between the range of -99P and 99P.
*3 Press the button to set between the range of 1 and 9999 (ms).
*4 Press the button to set the adjustment sensitivity to a range of between LEu1 and LEu3 and set the warning output level to a range of
between 0P and 100P.
*5 Cannot be selected when LV-S31 is connected.
*6 Press the button to switch between oFF/on/KEEP.
*7 The analog output upper limit can be set between 50 and 65535.
*8 Not available for zero line types.
*9 Monitor output type only (LV-N11MN).
*10 Press the button to toggle between Std/P~P_/b~b_/P_b~/P~b_.
*11 Press the button to set between the range of 100P and 200P.
*12 Not displayed when LV-S31 is connected.
*13 Main unit only.
*14 Only 2-output types (LV-N11 / N12).
*15 Press the button to select the User (user reset) or Auto (auto reset) resetting methods.
*16 Select the count method from oUr1, oUr2 or Auto. When Auto is selected, the one shot time can be set between 1 and 9999 (ms).
Press the button and the button simultaneously to return to the
previous setting option.
When the button is held down, the settings menu will end and the
received light intensity setting screen will appear.
Counter output mode *
16
Light intensity detection mode
Limit setting output mode *
15
Warning output mode
Timer OFF
Off-delay timer *
3
On-delay timer *
3
One-shot timer *
3
Settings complete
Return to normal display
(page 4-37)
(page 4-34)
(page 4-35)
(page 4-35)
(page 4-37)
(page 4-37)
(page 4-37)
(page 4-37)
MODE
MODE
MODE
MODE
MODE
MODE
MODE
Reference
MODE
MODE