3-3 Adjusting the Sensitivity
3
Basic Operation
3-15
- Digital Laser Sensor LV-N10 Series User's Manual -
This method is used when you want to position a workpiece.
1
Press the [SET] button
once when no workpiece is
present.
2
Position a workpiece such
that its edge aligns with the
center of the projecting
beam. Then, press and hold
the [SET] button for 3 sec-
onds or more. Release the
button when "SEt" flashes.
Calibration is complete after
the setting value flashes
momentarily, and then stops
(lights up).
Press the button to
adjust the setting value.
When performing two-point calibration on channel 2 of the 2-output type,
set the channel switch to "2".
Positioning Calibration
Workpiece
Reference
Setting
value
Time
Received
li
g
ht intensity
2
1
The setting value is determined as the value of light intensity received when
the workpiece comes into position.