Manual

12
Sensor Amplifier
*1 The input time is 25 ms (ON) / 25 ms (OFF) only when external calibration input is selected.
*2 Increases 30 mW (1 mA) for HIGH SPEED Mode
*3 When using expansion units, the working ambient temperature will change according to the following conditions.
Always install on a DIN rail (installed on the metal plate) and keep the output current to 20 mA / unit or less.
1 or 2 units connected: - 20 to + 55°C; 3 to 10 units connected: - 20 to + 50°C; 11 to 16 units connected: - 20 to + 45°C
When using the 2 output type, one unit is counted as two units.
*4 When connecting nine or more expansion units, ensure that the power voltage is 20 V or more.
*5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It dose not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit.
Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 x 860mW x 1) + (1.15 x 860mW x 2) = 2967mW max.
*6 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*7 When an amplifier is connected to the LV-NH100,LV-NH110 or LV-NH300 and used in HIGH SPEED mode, the power consumption is maximum. (989mW for NPN or 1127mW for PNP)
*8 Response time will be doubled from the normal response time when Double is set.
WARRANTIES AND DISCLAIMERS
KEYENCE, at its sole option, will refund, repair or replace at no charge any
defective Products within 1 year from the date of shipment. Unless stated
otherwise herein, the Products should not be used internally in humans, for
human transportation, as safety devices or fail-safe systems. EXCEPT FOR THE
FOREGOING, ALL EXPRESS, IMPLIED AND STATUTORY WARRANTIES,
INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NONINFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE SHALL NOT BE LIABLE
FOR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER
DAMAGES, EVEN IF DAMAGES RESULT FROM THE USE OF THE
PRODUCTS IN ACCORDANCE WITH ANY SUGGESTIONS OR INFORMATION
PROVIDED BY KEYENCE. In some jurisdictions, some of the foregoing warranty
disclaimers or damage limitations may not apply.
E 1101-3
Type 2 output 1 output 0-line Monitor output
Cable / Connector Cable M8 connector Cable
Main unit / Expansion unit Main unit Expansion unit Main unit Expansion unit Expansion unit Main unit
Model
NPN LV-N11N LV-N12N LV-N11CN LV-N12CN
LV- N10
LV- N11MN
PNP LV-N11P LV-N12P LV-N11CP LV-N12CP
Input/output
Control output 2 output 1 output N/A 1 output
External input 1 input 1 input N/A 1 input
Monitor output N/A 1 output
Response time
80 μs (HIGH SPEED) / 250 μs (FINE) / 500 μs (TURBO) / 1 ms (SUPER) /4 ms (ULTRA) / 16 ms (MEGA)
* 80 μs cannot be selected when LV-S31 / S62 / S63 is connected.
Output operation Light-ON / Dark-ON
Timer function
Timer OFF, OFF delay, ON delay, One-shot
Timer variable (1 ms to 9999 ms) Maximum error to setting value is ±10 % or less
Control output
NPN output
NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less
PNP output
PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less
Monitor output (Only LV-N11MN)
Voltage output: 1 to 5 V, load resistance: 10 k: or more,
repeat accuracy: ± 0.5% of F.S.
Response time: 1ms (HIGH SPEED / FINE / TURBO),1.2 ms (SUPER), 1.8 ms (ULTRA), 4.2 ms (MEGA)
External input
Input time 2 ms (ON) / 20 ms (OFF) or more
*1
Expansion units Up to 17 units can be connected in total. (The 2 output type is treated as two units.)
Protection circuit Protection against reverse power connection, output overcurrent, and output surge
Number of
interference
prevention units
Connect with
other than LV-S31
HIGH SPEED: 0, FINE / TURBO / SUPER: 2, ULTRA / MEGA: 4
(These numbers double when "Double" is selected.)
*8
Connect with
LV- S31
FINE: 2, TURBO / SUPER / ULTRA / MEGA: 4 (These numbers double when "Double" is selected.)
*8
Rated
Power voltage
*4
24 VDC (operating voltage 10-30 VDC (including ripple)), ripple (P-P) 10% or less, Class 2 or LPS
*6
Power
consumption
*5
NPN
Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)
*2 *7
Eco on: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)
*2
Eco full: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V)
PNP
Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)
*2 *7
Eco on: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)
*2
Eco full: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
Environmental
resistance
Operating ambient
temperature
- 20°C to + 55°C (no freezing)
*3
Operating ambient
humidity
35 to 85% RH (no condensation)
Vibration resistance 10 to 55 Hz, compound amplitude 1.5 mm, 2 hours for each of X, Y, Z axes
Shock resistance
500 m/s
2
, 3 times for each of X, Y, Z axes
Material
Housing Amplifier body and dust cover material: Polycarbonate
Cable PVC
Housing dimensions H 32.6 mm u W 9.8 mm u L78.7 mm
Weight Approx. 75 g Approx. 65 g Approx. 20 g Approx. 20 g Approx. 20 g Approx.75 g
2011
11526E 1022-4 96M11527