User guide

7-19
Chapter 7 RS-232C
7
Serial Commands to check the LS Settings
The following section provides information on command formats used to check setting
details.
Code
Command Response
S C , H E
,
a cr
S C , A R
,
a cr
S C , S E
,
a cr
S C , A T
,
a cr
S C , L E
,
a cr
S C , C A
,
h cr
S C , A V
,
h cr
S C , M E
,
h cr
S C , T M
,
h cr
S C , O F
,
h cr
S C , A U
,
h cr
S C , A O
,
h cr
S C , U P
,
h cr
S C , S D
,
h cr
S C , L W
,
h cr
S C , H H
,
h cr
S C , H I
,
h cr
S C , L O
,
h cr
S C , L L
,
h cr
S C , J O
,
h cr
S C , E H
,
h cr
S C , E L
,
h cr
S C
,
C A
,
h
,
i i cr
S C
,
A V
,
h
,
j
cr
S C
,
M E
,
h k
,
S C
,
T M
,
h l l l l
,
S C
,
O F
,
h m
n
m m m m m m m cr
,
S C
,
U P
,
h m m m m m m m m cr
,
S C
,
S D
,
h m m m m m m m m cr
,
S C
,
L W
,
h m m m m m m m m cr
,
S C
,
H H
,
h m m m m m m m m cr
,
S C
,
H I
,
h m m m m m m m m cr
,
S C
,
L O
,
h m m m m m m m m cr
,
S C
,
L L
,
h m m m m m m m m cr
,
S C
,
E H
,
h m m m m m m m m cr
,
S C
,
E L
,
h m m m m m m m m cr
,
S C , C L
,
a cr
S C
,
C L
,
a m m m m m m m m m m m m m m m m
,,
m m m m m m m m m m m m m m m m cr
,
,
S C
,
J O
,
h w w cr
,
S C
,
A U
,
h
,
S C
,
A O
,
h m m m m m m m m
,
m m m m m m m m cr
,
S C
,
H E
,
a
,
b cr
S C
,
A R
,
a
,
c cr
S C
,
S E
,
a
,
d d d d e
,
d d d d e cr
S C
,
A T
,
a
,
f f f cr
S C
,
L E
,
a
,
g g cr
Head
(Page 7-13)
Area
(Page 7-13)
SEG edge number
(Page 7-13)
Area check
(Page 7-14)
Level
(Page 7-14)
Calculation
(Page 7-14)
Average
(Page 7-14)
Measuring mode
(Page 7-15)
Offset
(Page 7-15)
Analog
Reference value
(Page 7-15)
Threshold
(Page 7-16)
Reference
value
(Page 7-16)
Logic calibration
(Page 7-18)
STANDARD
LOWER
HH
HI
LO
LL
Hold ON/OFF
(Page 7-18)
HOLD-H
HOLD-L
Self-timing
(Page 7-15)
j cr
crk
n cr
a : Area setting number
b : Head number
c : Area
dddd : Edge number
e : Edge mode
fff : Number of edges
gg : Threshold
h : Output setting number
ii : Calculation
jj : Averaging number
kk : Measuring mode
llll : Self-timing period
mmmmmmmm : Numeric value
nn : Analog scale
w : ON/OFF
Calibration setting
Tolerance setting Output setting
Area setting
Threshold
(Page 7-17)
UPPER
The above formats are examples with the Cr character used for delimiters.
If the KV-10/80 series is used (i.e., PLC is set as a D-MODE environment setting),
use the STX+ETX characters instead of Cr. (See page 7-6)
Refer to Outline of Command Formats on page 7-6 for commands in detail. When
the response for the setting change command is received by the LS-7000 Series,
the LS-7000 Series will return detailed data on the current settings in the LS-7000.