Manual

3-12
3
3 Connecting to DeviceNet
Output data buffer
The output data buffer refers to the area where parameters sent from the DeviceNet
master node to the LK-DN100 are stored.
A word is 16 bits.
Input control buffer
The input control buffer refers to the area where LK-DN100 statuses and responses to the
output control buffer control signals are stored.
LK-
DN100
Signal
direction
DeviceNet master node
Offset Signal name Explanation
Read
data
buffer
Word (14) SET_PRG_NUM Sets the program selection number from 0
to 7.
Word (15) System reserved
LK-
DN100
Signal
direction
DeviceNet master node
Offset Signal name Explanation
Write
control
buffer
Bit (0) CHG_PRG_ACQ Turns ON (1) when the program number
changeover process completes.
Bit (1) CHG_PRG_ERR Turns ON (1) when an error occurs during
the program number changeover process.
Bit (2) SYNC_TIM_ON_ACQ Turns ON (1) when the synchronized timing
ON process completes.
Bit (3) SYNC_TIM_ON_ERR Turns ON (1) when an error occurs during
the synchronized timing ON process.
Bit (4) SYNC_TIM_OFF_ACQ Turns ON (1) when the synchronized timing
OFF process completes.
Bit (5) SYNC_TIM_OFF_ERR Turns ON (1) when an error occurs during
the synchronized timing OFF process.
Bit (6) SYNC_ZERO_ON_ACQ Turns ON (1) when the synchronized zero
ON process completes.
Bit (7) SYNC_ZERO_ON_ERR Turns ON (1) when an error occurs during
the synchronized zero ON process.
Bit (8) SYNC_ZERO_OFF_ACQ Turns ON (1) when the synchronized zero
OFF process completes.
Bit (9) SYNC_ZERO_OFF_ERR Turns ON (1) when an error occurs during
the synchronized zero OFF process.
Bit (10) SYNC_RESET_ACQ Turns ON (1) when the synchronized reset
process completes.
Bit (11) SYNC_RESET_ERR Turns ON (1) when an error occurs during
the synchronized reset process.
Bit (12) System reserved
Bit (13) CHG_PRG_ENBLE Turns ON (1) when program changeover is
possible.