Manual

2-12
2
2 Connecting to CC-Link
Write
control
buffer
RX (n+13) CHG_PRG_ENBLE Turns ON (1) when program changeover
is possible.
RX (n+14) READY_FLAG Turns ON (1) when the controller is not
in setting mode, communicating,
running, Able Tuning, or setting scaling
from measurement data.
When OFF (0), the ***-ERR
corresponding to the ***-REQ turns ON
(1).
RX (n+15) SYSTEM_ERR_FLAG Turns ON (1) when the controller or
expansion unit has a system error.
When ON (1), all signals except
SYSTEM_ERR_NO become invalid.
RX (n+16*m+0) OUTm_LO Turns ON (1) when the comparator output
for OUTm is LO.
RX (n+16*m+1) OUTm_GO Turns ON (1) when the comparator output
for OUTm is GO.
RX (n+16*m+2) OUTm_HI Turns ON (1) when the comparator output
for OUTm is HI.
RX (n+16*m+3) OUTm_TIM_ON_ACQ Turns ON (1) when the timing ON process
for OUTm completes.
RX (n+16*m+4) OUTm_TIM_ON_ERR Turns ON (1) when an error occurs during
the timing ON process for OUTm.
RX (n+16*m+5) OUTm_TIM_OFF_ACQ Turns ON (1) when the timing OFF
process for OUTm completes.
RX (n+16*m+6) OUTm_TIM_OFF_ERR Turns ON (1) when an error occurs during
the timing OFF process for OUTm.
RX (n+16*m+7) OUTm_TIM_STATE Turns ON (1) when the timing for OUTm is
ON.
RX (n+16*m+8) OUTm_ZERO_ON_ACQ Turns ON (1) when the zero ON process
for OUTm completes.
RX (n+16*m+9) OUTm_ZERO_ON_ERR Turns ON (1) when an error occurs during
the zero ON process for OUTm.
RX (n+16*m+10) OUTm_ZERO_OFF_ACQ Turns ON (1) when the zero OFF process
for OUTm completes.
RX (n+16*m+11) OUTm_ZERO_OFF_ERR Turns ON (1) when an error occurs during
the zero OFF process for OUTm.
RX (n+16*m+12) OUTm_ZERO_STATE Turns ON (1) when the zero for OUTm is
ON.
RX (n+16*m+13) OUTm_RESET_ACQ Turns ON (1) when the reset process
completes for OUTm.
RX (n+16*m+14) OUTm_RESET_ERR Turns ON (1) when an error occurs during
the reset process for OUTm.
LK-
CC100
Signal
direction
CC-Link master station
RY
(Remote outputs)
Signal name Explanation