Manual

2-10
2
2 Connecting to CC-Link
n: varies according to the station number of the LK-CC100.
m (1 to 12): corresponds to the OUT number. m = 1 for OUT01, m = 2 for OUT02, etc.
Read
control
buffer
RY (n+16*m+3) OUTm_TIM_ON_REQ Requests timing ON to OUTm at the
rising edge from OFF (0) ON (1).
Ends the request at the falling edge
from ON (1) OFF (0).
RY (n+16*m+4) System reserved
RY (n+16*m+5) OUTm_TIM_OFF_REQ Requests timing OFF to OUTm at the
rising edge from OFF (0) ON (1).
Ends the request at the falling edge
from ON (1) OFF (0).
RY (n+16*m+6) System reserved
RY (n+16*m+7) System reserved
RY (n+16*m+8) OUTm_ZERO_ON_REQ Requests zero ON to OUTm at the
rising edge from OFF (0) ON (1).
Ends the request at the falling edge
from ON (1) OFF (0).
RY (n+16*m+9) System reserved
RY (n+16*m+10) OUTm_ZERO_OFF_REQ Requests zero OFF to OUTm at the
rising edge from OFF (0) ON (1).
Ends the request at the falling edge
from ON (1) OFF (0).
RY (n+16*m+11) System reserved
RY (n+16*m+12) System reserved
RY (n+16*m+13) OUTm_RESET_REQ Requests reset to OUTm at the rising
edge from OFF (0) ON (1).
Ends the request at the falling edge
from ON (1) OFF (0).
RY (n+16*m+14) System reserved
RY (n+16*m+15) System reserved
RY (n+16*13+0) System reserved
.
.
.
System reserved
LK-
CC100
Signal
direction
CC-Link master station
RY
(Remote outputs)
Signal name Explanation