Manual

1-5
1
1 Before Use
Connector
Terminal block
3 1 4 1.1 Disables control input, tolerance comparison and readout of
measurement values for OUT07 and higher.
4 2 1 2.0 Disables control input or tolerance comparison for any OUT,
and disables readout of measurement values for OUT3 and
higher.
5 2 2 2.0 Disables control input or tolerance comparison for OUT05
and on, and disables readout of measurement values for
OUT07 and higher.
6 2 3 2.0 Disables control input or tolerance comparison for OUT09
and on, and disables readout of measurement values for
OUT11 and higher.
7 2 4 2.0 Unused.
8 4 1 2.0 Disables control input or tolerance comparison for OUT03
and on, and disables readout of measurement values for
OUT07 and higher.
9 4 2 2.0 Disables control input and tolerance comparison for OUT11
and higher.
A 4 3 2.0 Unused.
B 4 4 - Cannot be used due to stress placed on network.
C 8 1 2.0 Disables control input and tolerance comparison for OUT07
and higher.
D 8 2 2.0 Unused.
E 8 3 - Cannot be used due to stress placed on network.
F 8 4 - Cannot be used due to stress placed on network.
Terminal name Function
FG Functional ground terminal.
Ground to a ground resistance of 100 ohms or less.
SLD Shield.
Connect shield wire from the dedicated CC-Link cable supporting Ver. 1.10
(OP-79426, OP-79427, etc.).
DG Communication ground
DB Communication signal Low
DA Communication signal High
Switch setting Multiple Station Version Remark