Manual

6
5. Safety features provided with the LK series
The LK series is provided with the following safety features. Make sure
these features function correctly before operating.
Key-operated laser switch
A key-operated switch controls
the LK series laser. Remove
the key when the laser is not in
use.
Laser radiation emission warning
(Is ON during laser emission.)
After the key-operated laser switch is set to the ON position, laser
radiation emission warning flashes for approximately 3 seconds before
laser emission. The LED lights during laser emission. The LED light can
be checked through protective goggles.
SAFETY PRECAUTIONS ON LASER PRODUCT
Remote interlock terminal
Laser emission can be stopped by disconnecting the REMOTE terminal
from the GND terminal.
Beam attenuator [with LK-501/503 only]
Laser emission is blocked by attaching the shutter.
Key-operated
laser switch
ONOFFLASER
LK-031
Laser radiation
emission warning
REMOTE24 VDC IN GND TIMING ZERO
+-