Manual
17
Response speed selection function
DIP switch 3
Set DIP switch 3 to select whether to output every measured value or
the average of 8 measured values (moving average).
LOW:
Outputs the value of the average of 8 measured values. Offers more
stable detection when the luster of the target varies greatly.
HIGH:
Outputs every measured value. Offers high-speed response when the
target vibrates or moves quickly.
FUNCTIONS DIP SWITCHES
Average response time LOW HIGH
LK-031/036 Approx. 4 ms Approx. 0.5 ms (no averaging)
LK-081/086/501/503 Approx. 8 ms Approx. 1.0 ms (no averaging)
Example: When LOW is set
Example: When HIGH is set
The HIGH setting is effective in detecting abrupt changes, such as height
differences.
LOW
HIGH
123
Analog
output
Analog
output
DIP switch
(HIGH)
DIP switch
(LOW)
LK-031
Analog
output
Analog
output
DIP switch
(HIGH)
DIP switch
(LOW)
LK-031