Instruction Manual

15
Model Sensor head LB-11(W)
Controller LB-70(W)
Reference distance
1.
100 mm
Measuring range ±40 mm
Light source Invisible infrared semiconductor laser,
Output: 3 mW (FDA), 2.5 mW (IEC), Pulse duration: 70 µs
Wavelength 785 nm
Laser
FDA(CDRH) 21CFR Part 1040.10
Class IIIb
Class IEC60825-1 Class 3R
Spot diameter
2.
1.0 x 2.0 mm
Linearity
3.
1.6% of F.S. (80 to 120 mm)
Resolution
4.
10 µm (at 500 ms)/40 µm (at 20 ms)/180 µm (at 0.7 ms)
STABILITY indicator LED (RED, GREEN, YELLOW)
Output Analog Voltage
5.
-4 V to +4 V (0.1 V/mm)
Impedance 100
Alarm
NPN open-collector: 50 mA (40 V) max. Residual voltage: 1 V max. (N.C.)
Zero-point adjustment range 60 mm to 140 mm
Span adjustment range 0.1 V/mm±30%
Response frequency DC to 700 Hz (at 0.7 ms)(-3dB)/DC to 18 Hz (at 20 ms) (-3dB)/
DC to 0.6 Hz (at 500 ms) (-3 dB)
Sensitivity WHITE, BLACK, and AUTO (switch-selectable)
Temperature fluctuation
3.
Sensor head 0.02% of F.S./°C
Controller 0.04% of F.S./°C
Laser control input NPN open-collector or non-voltage contact
Ambient light
6.
4,000 lux. max.
Ambient temperature 0 to +50°C (32 to 122°F), No condensation
Relative humidity 35 to 85%, No condensation
Power supply 12 to 24 VDC±10% Ripple (p-p): 10% max.
Power consumption 120 mA max.
Housing Sensor head Die-cast zinc-based alloy
Controller Polycarbonate
Weight (including cable) Sensor head Approx. 200 g
Controller Approx. 200 g
SPECIFICATIONS: LB-70(W)
1. Distance from the surface of the laser-
emitting portion of the sensor head.
2. The beam spot is visible when the object
(white paper) is placed at a distance of
100 mm from the laser-emitting portion
of the sensor head.
3. F.S. stands for a measuring range of 80
mm.
4. The value when the object (white paper)
is measured distance of 100 mm from
the laser-emitting portion of the sensor
head.
5. The range can be expanded to “-5 V to
+5 V” by using the 0-ADJ and SPAN
adjuster trimmers. The alarm output is
approx. 7 V.
6. Incandescent lamp or fluorescent lamp