User guide

Table Of Contents
2-7
- IV Series User's Manual (Monitor) -
Mounting the Sensor
Using the polarizing lter attachment
Do not remove the front cover of the sensor.
There are the polarized visible light lter
attachment (OP-87436) and the infrared
polarization lter attachment (OP-87437). Use
the correct polarization lter attachment in
accordance with the illuminant of the sensor light.
Failure to do so may lose the effect.
Adjust the brightness with the polarization lter
attachment mounted.
“Auto Brightness Adjustment” (Page 4-11)
For the color type, adjust the white balance with
the polarization lter attachment mounted.
“White Balance (for color type only)” (Page 6-41)
1
Mount the attachment by aligning the
concave part of the polarizing lter
attachment with the mounting screw of
the front cover of the sensor.
Concave part
Concave part
Front cover
mounting screw
Screw hole for
mounting the
attachment
2
Fix the polarizing lter attachment with
the attached dedicated screws.
Screw : M2.5 x 2
Use the attached dedicated screws.
Tightening torque : 0.25 to 0.35 N·m
Remove the protection
sheet (blue)
2
Installation and Connection