User guide

4-2 Basic Settings and Advanced Settings
4-23
IL-E
4
Setting Various Functions
IL-2000
The external input (timing input) operation used for "6. Hold Function" (page 4-15) is set.
If "Auto peak hold" or "Auto bottom hold" is set, this item is skipped.
For details, refer to the "6. Hold Function" (page 4-15).
The delay timer for the judgment output is set.
There are three judgment outputs as below.
HIGH judgment output (Black wire)
GO judgment output (Gray wire)
LOW judgment output (White wire)
The judgment output is turned ON/OFF according to the tolerance setting value and the
output state settings.
“3-4 Setting the Tolerance Setting Value” (page 3-10)
"5. Output State" (page 4-14)
Item Setting range Default value
Trigger level -9999.9 to 9999.9 100.0
Reference
The hysteresis presents the same value as the one set for "9. Hysteresis"
(page 4-26).
7. Timing Input
6K/
Item Setting range Default value
Timing Input LeveL (Level), edGe (Edge) LeveL
8. Delay Timer
&.;
Delay Timer Description
Default
value
Delay timer off
The delay timer is not used.
c
ON-delay timer
Time required to change the GO judgment output
operation from OFF to ON is delayed for specified time set
on the timer.
"ON-delay timer" (page 4-24)
OFF-delay timer
Time required to change the GO judgment output
operation from ON to OFF is delayed for specified time set
on the timer.
"OFF-delay timer" (page 4-25)
1-shot timer
When GO judgment output is turned ON, if the specified
time elapses, GO judgment output is automatically turned
OFF.
"1-shot timer" (page 4-25)