User guide
4-2 Basic Settings and Advanced Settings
4-13
IL-E
4
Setting Various Functions
The IL series cannot complete a measurement if it is outside the measurement range or if 
the light amount is excessive or insufficient. (If the measurement is impossible for a number 
of samples equal to the alarm number, "---" will appear.)
Details of operations when measurement is impossible are set with the alarm setting.
The alarm output is ON during normal measurement. It turns OFF when an alarm or error state occurs.
* If measurement is impossible immediately after powering on or immediately after reset 
input, the display [-----] is held.
4. Alarm Setting
#./
Setting value Description
Default 
value
Default
When measurement is impossible, this option sets the 
default number of samples for which the previous normal 
value is held.
This differs according to the set sampling rate.
c
Clamp
When measurement is impossible, the previous normal 
value is held until measurement is restored.
User setting
When measurement is impossible, this option sets the number 
of samples for which the previous normal value is held.
The settable range is as follows:
Point
• If the default or user setting is selected and measurement remains 
impossible after the number of alarms, the measured value is dis-
played as [-----]. This is called the alarm state.
• When the amplifier is in alarm state and valid measurement values 
are obtained for a number of samples equal to the averaging value 
+ 2, the amplifier recovers from the alarm state and displays the 
measured value.
• If measurement is restored not later than the number of sampling 
times specified for the default or user setting, the hold function is 
cancelled.
• The alarm output after power up or reset input is ON until the amplifier 
recognizes an unmeasurable state even if [
-----
] is displayed.
• The alarm output is turned ON once a reset is executed in 
response to reset input.
• The alarm output operates as a normally closed contact irrespective of 
how the output method is changed ( "5. Output State" (page 4-14)).
• The alarm output is not held by timing input.
Sampling rate Sampling rate
0.33 ms 6 times
Other than 0.33 ms 7 times
Setting range Default value
2 to 1000 times 7 times