Manual
4
GV-IM-E
 Detection method
The GV Series has two type of detection methods: "Distance detection method" and 
"Reference surface (DATUM) detection method".
The reference surface (DATUM) detection method can only be used when 
performing reference surface calibration.
Control output 2 is fixed to distance detection method for all operation modes.
 Distance detection method (Normal)
Detects the distance between the detection target and the sensor head, and 
then performs control output. The following table shows each operation mode 
and the auto calibration that can be used.
z Area detection mode (F-2 mode)
Operation image
When using the F-2 mode, the channel No. indicator switches in the following 
order each time the [MODE] button is pressed.
Configure the sensitivity setting in F-1 mode (with the default settings).
2-point calibration 
The setting is automatically calculated as the mean value detected from two 
points: with the workpiece and without the workpiece.
1 Press the [SET] button once 
without a workpiece in place.
The current value without the 
workpiece is read.
2 Place a workpiece in the 
detection position, and quickly 
press the [SET] button once 
again.
This concludes 2-point calibration 
and the sensor returns to the 
detection state.
If there is very little difference between the values obtained in 
Step 1 and Step 2, then "---" flashes in the setting value display 
area after calibration is complete. The setting value is still 
updated.
Fine-tune setting value
Use the [Up] and [Down] arrow buttons to fine-tune the setting value.
Reference surface (DATUM) calibration
Use DATUM calibration when comparator output cannot be performed 
correctly during 2-point calibration (due to problems such as chattering from 
the surface of the workpiece).
3 Press the [SET] button once without a workpiece in place 
(reference surface).
4 Using the same conditions, 
Item Setting range
Setting 
value
fine-
tuning
-199 to 999
Reference
DATUM
SET
MODE
1
2
Increases
the setting 
value
Decreases
the setting 
value
Using Basic Operations 
Configuring the Sensitivity Setting and 
Operation Mode
Operation mode Description
Usable
auto calibration 
General F-1
Normal detection mode
The most general mode.
ON/OFF judgment is performed 
based on one setting value.
2-point calibration
Full auto calibration
Maximum sensitivity 
setting
Special
F-2
Area detection mode
On/OFF judgment is performed 
on an area based on two 
settings.
2-point area calibration
1-point area calibration
A-1
Edge hold mode
Detects the change in distance 
(derivation) to the target and 
holds the display.
2-point calibration
Full auto calibration
Maximum sensitivity 
setting
A-2
Surface detection mode
When multiple beams of light are 
reflected from the detection 
target, the closest reflected light 
is judged as the detection value.
2-point calibration
Full auto calibration
Maximum sensitivity 
setting
Note
OFF
OFF
ON
LOW setting value
HIGH setting value
Only this will turn ON.
1
2
1
2
1
2
1
2
MODE
Press once.
MODE
Press once.
MODE
Press once.
MODE
Press once.
Control output 1 
(black) HIGH setting 
value
• Channel No. 1 
indicator lights up
Control output 1 
(black) LOW setting 
value
• Channel No. 2 
indicator lights up
Control output 2 
(white) HIGH setting 
value
• Channel No. 1 
indicator flashes
Control output 2 
(white) LOW setting 
value
• Channel No. 2 
indicator flashes