User Manual
11
GT2-70-M-E
<<When using a model other than GT2-71MCN/MCP (analog output type)>>
<<When using GT2-71MCN/MCP (analog output type)>>
■
Additional function setting mode
You can set the following functions in the additional function setting mode.
●
How to enter the added function setting mode
Enter the added function setting mode by the following procedure.
•
In the main display, press the [MODE] button and the left Arrow 
button at the same time for at least two seconds. 
Reference
The items that can be selected (displayed) are different 
depending on the settings in "A1. Calculation mode". 
(When the expansion unit is not added, the items that can be 
selected (displayed) are the same as for "noCALc".
*1 This can be set only on the main unit that an expansion 
unit is added.
*2 On the expansion unit, this can be set only when "C5.rEF 
(Reference difference) is selected in "A2. Calculation Mode".
*3
This can be set only when "C5.rEF (Reference 
difference)" is selected in "A2. Calculation method".
 Special output setting
Not used
5-output
Limit output
Limit output user setting
All GO
All limit output
*
1
*
1
OOOO O -
O
 O*
2
OO
 O*
3
-
OO- - O O
A1
.
Calculation mode
16
.
Special output
setting
Reference
 position set
Limit output HH side teaching
 Only available when "Lt.USEr" is selected in [ Special output setting].
MODE
Setting value 
input screen
 Limit output HH side criterion position setting
 Only available when "Lt.USEr" is selected in [ Special output setting].
Reference
 position set
Limit output LL side teaching
 Only available when "Lt.USEr" is selected in [ Special output setting].
MODE
Setting value 
input screen
 Limit output LL side criterion position setting
 Only available when "Lt.USEr" is selected in [ Special output setting].
Default
Free range settings
 Analog range setting
MODE
 Free range settings (Hi)
 Only available when "FrEE" is selected in " Analog range setting".
Setting value 
input screen
No.
Item Description
Select preset data Select the data to use when performing the preset.
Store preset value Set whether or not to save "zero-point correction".
Preset point
Set the memory method for "zero-point 
correction" when using the bank function.
Power-save 
function (ECO)
To decrease the power consumption or not to 
display the numerical value, set this function.
Jam detection function
When the spindle does not fully extend.
-
Jam detection teaching
Set the reference position for the jam detection.
Jam detection 
check point setting
Set the position to perform the jam detection 
function with the reference position being 0.
MODE
Setting value 
input screen
 Free range settings (Lo)
 Only available when "FrEE" is selected in " Analog range setting".
GT2-71GT2-71
Left Arrow button
[MODE] button
Main screen
R.V. value
 Select preset data
P.V. value
MODE
 Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].
YES
 Store preset value
NO
MODE
  Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].
Common for 
all banks
 Preset point setting
Save for 
each bank
MODE
  Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].
OFF
 Power-save function
ECO Half
ECO All
MODE