Troubleshooting
When there is a malfunction, the status light on the sensor amplifier
lights in red.
If you are using a DL Series Communication Unit (excluding DL-RB1A),
details of the error can be checked via the Communication Unit. See
the DL Series manuals for information on using the Communication
Units.
Item
Reference
chapter
Origin Alignment Chapter 3
Setting the Tolerances Chapter 3
HH/Setting the HH/LL Criterion Value Chapter 3
Preset Function (Adding or Subtracting a Desired Value) Chapter 3
Bank Function (Registering Multiple Criterion Values and
Preset Values)
Chapter 3
Reset Input (Resetting Internal Values) Chapter 3
Hysteresis Chapter 3
Initialization (Initial Reset) Chapter 3
Judging with the Current Value Chapter 4
Judging after the Detection Value is Stabilized Chapter 4
Judging by the Maximum Value (Peak Hold) Chapter 4
Judging by the Minimum Value (Bottom Hold) Chapter 4
Judging with the Difference between Maximum and
Minimum Values (Peak to Peak Hold Detection Mode)
Chapter 4
Holding HIGH/LOW Output (NG Hold) Chapter 4
Detection Mode Chapter 5
Hold Update Method Chapter 5
Response time Chapter 5
Timing Type Chapter 5
Self-timing Level Chapter 5
Self Timing Delay Types Chapter 5
User-specified Delay Time Chapter 5
Static Hold Delay Stability Chapter 5
Static Hold Delay Stability Width Chapter 5
Measurement Direction Chapter 5
Multiplier Chapter 5
Batch Input Settings Chapter 5
Special Output Setting Chapter 5
Limit Output HH Side Teaching Chapter 5
Limit Output HH Side Criterion Position Setting Chapter 5
Limit Output LL Side Teaching Chapter 5
Limit Output LL Side Teaching Criterion Position Setting Chapter 5
Select Preset Data Chapter 5
Store Preset Value Chapter 5
Preset Point Chapter 5
Power Save Function Chapter 5
Jam Detection Function Chapter 5
Jam Detection Teaching Chapter 5
Jam Detection Checkpoint Setting Chapter 5
Calculation Setting Mode Chapter 5
Timing Chart Chapter 5
Item
Reference
chapter
List of Optional Parts Chapter 1
Replacing the Contact Appendix
Replacing the Dust Boot Appendix
How to Mount the Lift Lever Appendix
Problem Cause Corrective action
Sensor head
error
The sensor head is
disconnected.
The sensor head cable is
broken.
The sensor head is
damaged.
Connect the sensor
head.
Replace the sensor
head cable.
Replace the sensor
head.
EEPROM
error
Failed to write data.
• Turn the equipment off
and on, and perform
initial reset. (If this
does not solve the
problem, the
equipment may be
damaged, or may have
reached the end of its
service life. Replace
the amplifier unit.)
Jam
detection
error
The spindle is jammed.
(When using the jam
detection function)
If the spindle is
jammed and does not
move, replace the
sensor head.
Use a Communication
Unit to check that the
timing input is
appropriate.
Self timing
delay error
The value fell below (rose
above) the timing level
during the set delay time.
The value fell below (rose
above) the timing level
before the detection status
was stable and the
criterion level (P.V. value)
was fixed when using
static hold internal timing.
The value rose above (fell
below) the timing level,
then fell below (rose
above) the timing level
before the criterion level
(P.V. value) was fixed when
using delay timer internal
timing.
Make sure that the
value does not fall
below (rise above) the
timing level before the
criterion value is fixed.
Alternatively, lengthen
the static hold delay
stabilizing amplitude
so that the criterion
value can be easily
fixed.
Unit number
error
• When using the calculation
function, the number of the
expansion unit when the
power is turned ON differs
from the number of the
expansion unit in the
memory of the main unit
when the calculation is set.
• When using the calculation
function, a model other
than the GT2-500/70
Series is added.
Reset the calculation
mode or perform initial
reset of the main unit.
Perform initial reset via
the Communication
Unit. See the DL
Series manuals for the
method.
Calculation
error
When using the reference
difference calculation
function, an error occurred
in the main unit.
When using other than the
reference difference
c
alculation function, an
error occurred in an
expansion unit.
Check each main/
expansion unit for the
cause of the error.
Calculation
only mode
error
The sensor head is
connected to the main unit
in which the calculation
only mode is set.
Remove the sensor
head from the main
unit or set a mode
other than the
calculation only mode.