Connecting and Mounting the Sensor Head
■
Names of parts of the sensor head
* Not included in the GT2-P12KL/P12L.
●
GT2-H12K(L)(F)(LF)/H12(L)(F)(LF)/H32(L)/H50
●
GT2-A12K(L)/A12(L)/A32/A50
■
Connecting the sensor head connection cable
●
For GT2-P***/PA***
1
Insert the sensor head connection 
cable into the cable connector on the 
relay connector cable.
2
Secure the connector with the sensor 
head connection cable screw.
●
For units other than GT2-P***/PA***
1
Insert the sensor head connection 
cable into the cable connector of the 
sensor head.
2
Secure the connector by rotating the 
grooved portion of the sensor head 
connection cable. 
•
To disconnect the sensor head connection cable, reverse the steps above.
■
Connecting the amplifier
1
Remove the lock cover of the connector of the sensor head 
connection cable, and insert the sensor head connection cable 
into the connector on the back of the amplifier until it clicks.
2
Put the lock cover on the connector, and lock the lock cover.
■
Mounting the sensor head
●
Mounting directly to a jig
Before mounting the sensor head directory to a jig, create a hole on the 
jig. Attach the sensor head using the optional head mounting bracket 
sold separately. A mounting bracket is provided with the GT2-P12KF/
P12F/H12K(L)F/H12(L)F as standard. Attach it with the supplied nut.
NOTICE
• When connecting the connector, be sure to insert it 
straight, and tighten it securely. (Recommended 
tightening torque: 0.4 to 0.5 N
•
m*)
If the connection is not tight enough, the connector 
may be loosened by vibration or other causes, 
leading to a connection failure.
(* After tightening it firmly by hand, use pliers or 
other tools to rotate it about 30° for further 
tightening.)
• When the head is attached to a moving part, and 
the cable will be repeatedly bent, ensure that the 
cable between the sensor head and relay 
connector does not bend. Instead, bend the sensor 
head cable connecting the relay connector and the 
amplifier.
Operation indicator
Relay connector
Cable 
connector
Dust boot
Mounting fixture
Dust boot
*
Spindle
Contact
Dust boot
●
GT2-P12K(L)/P12(L)
●
GT2-P12KF/P12F
Cable between 
the sensor 
head and relay 
connector
●
GT2-P
A
12K/P
A
12
Relay connector
Cable 
connector
Cable 
connector
Cable 
between the 
sensor head 
and relay 
connector
Operation indicator
Cable between 
the sensor 
head and relay 
connector
Mounting fixture
Operation indicator
Contact
Spindle
Air supply hole
Dust seal
*1 A mounting bracket is attached to 
GT2-H12KF/H12F/H12KLF/H12LF.
*2 Not included in the GT2-H12KL/H12L/H12KLF/H12LF.
Contact
Head indicator
Head indicator
Contact
Dust boot*
3
Bracket fixing 
part
Cable connector
Cable connector
Bracket fixing
 part*
1
Dust boot*
2
Contact
Dust boot
Spindle
*3 Not included in the GT2-H32L.
Dust boot
Dust boot*
Dust boot
Coupling socket
Coupling socket
Air cylinder
Air cylinder
Head indicator
Head indicator
Cable connector
Cable connector
Exhaust valve
Exhaust valve
Spindle
Contact
Mounting fixture
Mounting fixture
Contact
Contact
* Not included in the GT2-A12KL/A12L.
NOTICE
• When connecting the connector, be sure to insert it 
without tilt, and tighten it securely. (Recommended 
tightening torque: 0.4 to 0.5 N•m*)
If the connection is not tight enough, the connector 
may be loosened by vibration or other causes, 
leading to a connection failure.
(* After tightening it strongly by hand, use pliers or 
other tools to rotate it about 30° for further 
tightening.)
• The M8 L-shaped connector (GT2-CHL*M) cannot 
be used with the GT2-H32(L)/H50/A32/A50.
NOTICE
To disconnect the sensor head connection cable, 
press and hold the lock lever on the side of the 
connecter and disconnect the cable.
Arrow
click
Lock cover
Unlocked
Orient the connector so that the lock lever is on the right side.
Lock cover
Locked
Tightening sleeve
Key wrench
Nut
Options of the head mounting 
bracket A (OP-76874)
Tightening sleeve
Key wrench
Nut
Options of the head mounting 
bracket D (OP-84327)
Tightening sleeve
Key wrench
Nut
Options of the head mounting 
bracket C (OP-84396)
●
GT2-P12K(L)/P12(L)/PA12K/PA12/
H12K(L)/H12(L)/A12K(L)/A12(L)
●
GT2-H32(L)/H50/A32/A50
NOTICE
When mounting the 
GT2-H32L facing 
upward, be sure to 
use the mounting 
holes on the side of 
the sensor head. If 
the sensor head is 
mounted using head 
mounting bracket D, 
the spindle may not 
fully extend.
Mounting 
illustration