Owner manual
12
GT2-100-M-E
■
Additional function setting mode
You can set the following functions in the additional function setting mode.
* Can be set only on ID00.
●
How to enter the added function setting mode
Enter the added function setting mode by the following procedure.
•
In the main display, press the [MODE] button and the left Arrow 
button at the same time for at least two seconds. 
No.
Item Description
Select preset data
Select the data to use when performing the preset.
Store preset value
Set whether or not to save "zero-point correction".
Preset point
Set the memory method for "zero-point 
correction" when using the bank function.
Power-saving 
function (ECO)
To decrease the power consumption or not to 
display the numerical value, set this function.
Jam detection 
function
When the spindle does not fully extend.
-
Jam detection 
teaching
Set the reference position for the jam 
detection.
Jam detection 
check point setting
Set the position to perform the jam detection 
function with the reference position being 0.
Batch setting*
Set whether or not to apply the preset 
performed on ID00 to all IDs.
Valid ID 
Setting*
You can set the number of sensor heads 
(expansion units) that can be connected to the 
amplifier. The number of connectable sensor heads 
changes in accordance with the number of the 
installed expansion boards (one to three boards). 
Reference
 position set
Limit output HH side teaching
Only available when "Lt.USEr" is selected in [ Special output setting].
Setting value 
input screen
 Limit output HH side criterion position setting
Only available when "Lt.USEr" is selected in [ Special output setting].
Reference
 position set
Limit output LL side teaching
Only available when "Lt.USEr" is selected in [ Special output setting].
Setting value 
input screen
 Limit output LL side criterion position setting
 Only available when "Lt.USEr" is selected in [ Special output setting].
Left Arrow button
[MODE] button
Main screen
R.V. value
 Select preset data
P.V. value
 Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].
YES
 Store preset value
NO
  Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].
Common for 
all banks
 Preset point setting
Save for 
each bank
  Not available to set on the main unit for which "CAL.noH" is selected in [ Calculation mode].
OFF
 Power-saving function
ECO Half
ECO All
 Jam detection function
OFF
ON
User
  Not available to set on the main unit that selects "CAL.noH" in [ Calculation mode], and 
 the main unit and expansion unit that selects values other than "t-in" in [ Timing type].
Jam detection teaching
  Available to set when "USEr" is selected in [ Jam detection function].
Reference
 position fixed
Setting value 
input screen
  Available to set when "USEr" is selected in [ Jam detection function].
 Jam detection point setting
  This can be set only on the main unit (ID00).
 Batch setting
Separate
Batch