Owner's manual
3-3 Adjusting Sensitivity
3
Basic Operation
3-14
- Digital Fiber Sensor FS-N10 Series User's Manual -
This method is used when you want to position a workpiece.
1
Press the [SET] button 
once when no workpiece 
is present.
2
Position a workpiece such 
that its edge aligns with 
the center of the project-
ing beam. Then, press 
and hold the [SET] button 
for 3 seconds or more. 
Release the button when 
"SEt" flashes.
Press the   button to 
adjust the setting value.
When performing two-point calibration on channel 2 of the 2-output type,
set the channel switch to " ".
Positioning Calibration
Workpiece
Reference
Setting
value
Time
Received 
li
g
ht intensity
2
1
Calibration is complete after the setting value flashes momentarily, and then
stops (lights up).
The setting value is determined as the value of light intensity received when
the workpiece comes into position.