Owner's manual
6-5 Index 
6-12
- Digital Fiber Sensor FS-N10 Series User's Manual -
6
Appendix
Purpose Description Operation procedures
Reference
page
Swiching the 
output
1Swiching the output. (L-on/D-on)
1. Press the [MODE] button.
2. Switch with the   ( ) button.
3-4
Adjusting the 
sensitivity and 
integrating the 
display to "100.0" 
and ".0"
2
Set the current received light intensity 
to "100.0". (Preset)
Press the [PRESET] button while the PST 
indicator is OFF.
3-6
3
When preset is valid, register the 
received light intensity ".0". 
(Work-preset)
*
After step 7, press the [PRESET] button + 
button in the state to be set as ".0".
3-7
4
Set the received light intensity slightly 
higher than when the setting was 
made, to "100.0". (Maximum sensitivity 
preset)
*
While the PST indicator is OFF, press and hold 
the [PRESET] button. Reflective model: When 
no workpiece is present. Thrubeam/Retro-
reflective model: When a workpiece is present.
3-8
5
Automatically register "100.0" and ".0" 
when workpiece passes by. (Full Auto 
preset)
*
Press and hold the [PRESET] button while the
PST indicator is OFF.
3-9
6 Cancel the various preset functions. Press and hold the [PRESET] button. 3-6
Adjusting the 
sensitivity
7
Set the setting value at the midpoint 
between the received light intensity 
values when a workpiece is present 
and absent. (2-point calibration)
1. Press the [SET] button once when a work-
piece is present.
2. Press the [SET] button once when no work-
piece is present.
3-11
8
Set the setting value slightly higher 
than the received light intensity value 
at which the setting was made. (Maxi-
mum sensitivity calibration)
Reflective model: Press and hold the [SET] but-
ton when no workpiece is present. Thrubeam/
Retro-reflective model: Press and hold the
[SET] butt
on when a workpiece is present.
3-12
9
Set the setting value automatically 
when a workpiece is passing through. 
(Full auto calibration)
Press and hold the [SET] button  while the
workpiece passes through.
3-13
10
Set the setting value to the base point 
where the workpiece is positioned. 
(Positioning calibration)
1. Press the [SET] button once when no work-
piece is present.
2. Press and hold the [SET] button at the posi-
tioning point.
3-14
11 Finely adjust the setting value directly.
Press the   ( ) button.
1-4
Shifting the 
received light 
intensity to "0"
12
Set the current display to "0". (Zero 
shift)
Press the [PRESET] button +   button when
the PST indicator is OFF. 
3-16
13 Cancel the z
ero shift function. Press and hold the [PRESET] button. 3-16
Need to prevent 
the received light 
intensity from 
becoming satu-
rated.
14
Automatically adjusts to appropriate 
light emission and light receiving sen-
sitivity.
Briefly press [MODE] + [SET] buttons with the
amount of received light in maximum-saturated
condition.
3-18
12
Manual button
[MODE] 
button
Power select switch 
(1-output type))
[PRESET] 
button
[SET] button
Operation indicator 
(1-output/Zero line type)
DTM 
indicator
PST 
indicator
Operation 
indicator 
(2-output type)
Channel select 
switch (2-output type)
Quick Reference