Instruction Manual

13
SPECIFICATIONS
Type Threaded, non-shielded type
Size M8 M8 M16 M22
Sensor head EX-008 EX-008 EX-016 EX-022
Controller EX-501(W) EX-502(W) EX-505(W) EX-510(W)
Measuring range 0 to 1 mm 0 to 2 mm 0 to 5 mm 0 to 10 mm
Output voltage 0 to 5V
Output impedance 100
Output current 4 to 20 mA (Applicable load: 0 to 350 )
Resolution 0.03 % of F.S. (RESPONSE = 3, 4)
Response time 0.1 ms (RESPONSE = 1)
(Response mode) 1 ms (RESPONSE = 2)
10 ms (RESPONSE = 3)
100 ms (RESPONSE = 4)
Linearity ±0.3 % of F.S. (RESPONSE = 2, 3, 4)
Auto-zero function / Auto-span function
Functions Response time selector function / Preset metal characteristic memory function
Cable length selector function / Interference suppression function
Temperature Sensor head 0.03% of F.S./°C
1.
fluctuation Controller
0.04% of F.S./°C
Power supply voltage 12 to 24 VDC ±10%, Ripple (P-P): 10% max.
Current consumption 220 mA max.
Sensor head -20 to +105°C (-4 to 221°F), No freezing
Controller 0 to +50°C (32 to 122°F), No freezing
Relative humidity 35 to 85%, No condensation
Vibration 10 to 55 Hz, 1.5 mm double amplitude in X, Y and Z directions, 2 hours respectively
Enclosure rating Sensor head: IP-67
Sensor head Approx. 50 g Approx. 50 g Approx. 63 g Approx. 80 g
Controller Approx. 360 g
NPN open-collector: 100 mA (40 V) max.
Residual voltage: 1 V max. (N.C.)
The above data is obtained using an aluminum target (A5052 t = 1 mm). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these
materials.
1. EX-008: When the distance between the sensor head and target is half the maximum measuring distance and the operating temperature is 10 to 40°C (50 to 104°F).
EX-016, 022: When the distance between the sensor head and target is half the maximum measuring distance and the operating temperature is 0 to 50°C (32 to 122°F).
Analog
output
Ambient
temperature
Model
Weight
Disconnection alarm output