3-3 Explicit Messaging
3-25
3
Communicating with the GT-70A series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT-70A) -
 Response format
 •  When normal (for writing response data of WORD, UINT, or DINT type)
 •  When abnormal
The following formats are  used to activate the key lock on all  sensor  amplifiers
connected to the DL-DN1.
 Command format
Service data
Error code 0Eh is returned if the DL-DN1 is connected with any sen-
sor amplifier that does not support key lock or full key lock. (The set-
tings of such non-supported sensor amplifiers remain unchanged.)
 Response format
 •  When normal
 •  When abnormal
Responder 
node address 
 Service Code 
 0004h **h 90h 0000h 
 Response data 
 Number of received bytes  
Responder 
node address
 Service Code 
 0004h **h 94h FF**h 
 Response data 
(Error code) 
 Number of received bytes  
Locking Sensor Amplifiers
Service da ta Action Description
0000h
Deactivate key lock Deactivates key lock.
0001h
Activate key lock Activates key lock.
Destination 
node address 
 Service 
Code 
 **h 4Ch 0067h 0000h (See below) 
 Class ID 
 Instance ID   Service data 
Point
Responder 
node address 
 Service Code 
 0004h **h CCh 0000h 
 Response data  Number of received bytes  
Responder 
node address
 Service Code 
 0004h **h 94h FF**h 
 Response data 
(Error code) 
 Number of received bytes  