User Manual
3-2 I/O Communication
3-7
3
Communicating with the GT-70A series
- DeviceNet Compatible Network Unit DL-DN1 Userโs Manual (GT-70A) -
The device map varies depending on the operating mode of the DL-DN1.
Access each device in a manner suitable for the selected operating mode.
 "Status" (page 3-7)
 "Output" (page 3-9)
 "Comparator Value (P.V. Value)" (page 3-9)
 "External input" (page 3-11)
 "Changing a bank" (page 3-12)
 "Rewrite setting value" (page 3-13)
Status
IN area
n: The first device number assigned to the DL-DN1
๎ Status details
Device Maps
 Device 
(DEC) 
 Name 
 Bit 7   Bit 6   Bit 5   Bit 4   Bit 3 Bit 2   Bit 1   Bit 0 
 Bit 15   Bit 14   Bit 13 Bit 12   Bit 11   Bit 10   Bit 9   Bit 8 
 n Status 
 Reserved Reserved Reserved 
 Error ID 
number 
(MSB) 
 Error ID 
number 
 Error ID 
number 
 Error ID 
number 
 Error ID 
number 
(LSB) 
 Error state   Reserved 
 Sensor 
ready 
 Error code 
(MSB) 
 Error code   Error code   Error code 
 Error code 
(LSB) 
Name Description Reading range
Error status
An error occurred with the DL-DN1 or sensor  amplifier, or the
DL-DN1 is not communicating properly with the sensor amplifier.
If an error exists, the error ID number and error code are stored.
0: No Error
1: Error
Sensor ready
The sensor amplifier has started and is ready. 0: Starting
1: Ready
Error ID number
The error ID number is stored in the range of bit 0 (LSB) to bit 4
(MSB).
 "Error information list"
(page 3-8)
Error code
The error code is  stored in the range of bit 8 (LSB) to bit 12
(MSB).