User Manual
3-2 I/O Communication
3-6
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT-70A) -
3
Communicating with the GT-70A series
"3-output + current value" mode
5-output mode
"5-output + current value" mode
 3-output + monitor 
 No extended mode   Yes - - - 
 3-input - Yes Yes Ye s 
 Bank change   - - Yes - 
 Setting value rewrite   - - - Ye s 
 Area IN OUT IN OUT IN OUT IN OUT 
 Number of sensor amplifi ers 
 1 14 
 0 
 20 
 6 
 24 
 10 
 28 
 24 
 2 18 24 28 32 
 3 22 28 32 36 
 4 26 32 36 40 
 5 30 36 40 44 
 6 34 40 44 48 
 7 38 44 48 52 
 8 42 48 52 56 
 9 46 52 56 60 
 10 50 56 60 64 
 (b
ytes) 
 5-output 
 No extended mode   Yes - - - 
 5-input - Yes Yes Yes 
 Bank change   - - Yes - 
 Setting value rewrite   - - - Yes 
 Area IN OUT IN OUT IN OUT IN OUT 
 Number of sensor amplifi ers   1-10 12 0 22 10 26 14 34 40 
 (bytes) 
 5-output + current value 
 No extended mode   Yes - - - 
 5-input - Yes Yes Ye s 
 Bank change   - - Yes - 
 Setting value rewrite   - - - Ye s 
 Area IN OUT IN OUT IN OUT IN OUT 
 Number of sensor amplifi ers 
 1 18 
 0 
 28 
 10 
 32 
 14 
 40 
 40 
 2 22 32 36 44 
 3 26 36 40 48 
 4 30 40 44 52 
 5 34 44 48 56 
 6 38 48
 52 60 
 7 42 52 56 64 
 8 46 56 60 68 
 9 50 60 64 72 
 10 54 64 68 76 
 (bytes) 