User guide

3-3 Explicit Messaging
3-35
3
Communicating with the IL Series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (IL) -
*1 The error content of the sensor amplifier can be checked by noting the ON/OFF
state of each bit.
OFF (0): No error; ON (1): Error
More than one error may occur simultaneously. For details of each error, refer to
the IL Series User's Manual.
*2 Details of output status can be checked by noting the ON/OFF state of each bit.
*3 Use this parameter in combination with the comparator value property or with
the comparator value "invalid," "over," or "under."
*4 When using the IL-300/IL-600, -999.99 to +999.99, and when using the IL-2000,
-9999.9 to +9999.9.
*5 - When in sample hold:
Value "-99.998" is output.
- When not in sample hold:
The peak value encountered during the sampling period is output.
*6 - When in sample hold.
Value "-99.998" is output.
- When not in sample hold:
The b
ottom value enc
o
untered during the sampling period is output.
*7 If the sensor amplifier is in error, the analog voltage output is +5.500 and the
analog current output is +03.00. (For overcurrent errors and EEPROM errors,
the voltage value (current value) based on the measurement value.)
*8 If a prohibited combination of functions is written, it results in "abnormal setting
(1)." For details of each function, refer to the IL Series User's Manual.
*9 The "initial reset request" motion command result is included in this item.
Regarding data category N x 10 + 1 Data No. 79 (EEPROM writing result), a "0:
writing in progress" status is maintained for 2 seconds after completion of the
final write command transmission to the nonvolatile memory (EEPROM). Writing
begins 2 seconds later, and if completed normally, the result is "1: successfull
y
co
mpleted".
[Example] After every-second write command transmissions, a "0: writing in
progress" status is established for 2 seconds. A "0: writing in
progress" status is maintained for 2 seconds after completion of the
final write command transmission, and writing then begins 2 sec-
onds later, with a result of "1: successfully completed".
However, writing begins immediately following a initial reset executed in
response to a data category N Data No. 69 "initial reset" request. A "1: success-
fully completed" result then occurs if all parameters have been saved to the non-
volatile memory (EEPROM) approximately 3 seconds later.
Nx10+6
6F
Product name 4
*18 R
Main unit: ""
Expansion unit: ""
70 to
83
Reserved
8C
Product name (16-byte reading)
*21
Main unit: "IL-1000/1500"
Expansion unit: "IL-1050/1550"
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range