User guide

3-3 Explicit Messaging
3-32
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (IL) -
3
Communicating with the IL Series
Nx10+2
78
Analog output - lower limit value
(BANK 3)
*4
*16
R/W
-10.000 -99.999 to +99.999
79 to
83
Reserved
Nx10+3
64
Group-3 entry count
R20
65
Key lock function
R/W 0
0: Release
1: Key lock
66
Bank function
*13 R/W 0
0: Switched to Bank 0
1: Switched to Bank 1
2: Switched to Bank 2
3: Switched to Bank 3
67
Timing input
*14 R/W 0
0: Timing input OFF
1: Timing input ON
68
Laser emission stop input
*14 R/W 0
0: Emission stop input OFF
1: Emission stop input ON
69 to
6B
Reserved
6C
Sub display's screen
R/W 0
0: R.V. value display screen
1: Analog output value screen
2: HIGH setting value screen
3: LOW setting value screen
4: Shift target value screen
5: Calculated value display screen
6D
System parameter settings
*11 R/W 0
Main unit: 0 - 9
Expansion unit: 0 - 1
6E
Tolerance tuning - tolerance setting
range
*15 R/W 0.200
0 to 99.999
6F
Calibration function
R/W 0
0: Initial state
1: User setting
70
Calibration function SET1
*4 R/W 0.000
-99.999 to +99.999
71
Calibration function SET2
*4 R/W 5.000
-99.999 to +99.999
72
Calculated value calibration function
*16 R/W 0
0: Initial state
1: Calculated 2-p calibration
2: Calculated 3-p calibration
73
Calculated value two-point calibration
function SET1
*4
*16
R/W 5.000
-99.999 to +99.999
74
Calculated value two-point calibration
function SET2
*4
*16
R/W 10.000
-99.999 to +99.999
75
Calculated value three-point
calibration function SET1
*4
*16
R/W 5.000
-99.999 to +99.999
76
Calculated value three-point
calibration function SET3
*4
*16
R/W 10.000
-99.999 to +99.999
77 to
83
Reserved
Nx10+4
64
Group-4 entry count
R31
65
Calculation function
*16 R/W 0
0: OFF
1: Addition mode
2: Subtraction mode
66
Reserved
67
Measurement direction
R/W 0
0:nor
1:rEv
68
Sampling cycle
R/W 0
0:dEFLt
1:0.33ms
2:1ms
3:2ms
4:5ms
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range