3-3 Explicit Messaging
3-26
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (IL) -
3
Communicating with the IL Series
Error code 0Eh is returned if the DL-DN1 is connected with any sen-
sor amplifier that does not support key lock or full key lock. (The set-
tings of such non-supported sensor amplifiers remain unchanged.)
Response format
When normal
When abnormal
The following tables list the command parameters used in explicit messaging to read/
write the settings and status of sensor amplifiers and to issue motion commands.
For details about how the master unit performs explicit messaging using command
parameters, see:
"Issuing a Motion Command to a Sensor Amplifier" (page 3-22)
"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-23)
Common command parameter list
The table below describes command parameters which are common to the DL-DN1.
InstID: Instance ID; AttrID: Attribute ID
Attribute R: Read; R/W: Read/Write
Point
Responder
node address
Se rv ice Code
0002h **h CCh 0000h
Response data Number of receiv ed b ytes
Responder
node address
Se rv ice Code
0002h **h 94h FF**h
Response data
(Error code)
Number of receiv ed b ytes
Command Parameter List
InstID
(DEC)
AttrID
(HEX)
Name Description
Attribute
Data
type
Default
value
Parameter range
0
64 Status
Bit 0 - 12: Unused
Bit 13: Sensor ready
Bit 14: Warning status
Bit 15: Error status
RWORD0
Status details
(page 3-7)
65 Error status
The error status values of sensor
amplifiers (ID 01 to ID 04) are output
as they are assigned to bits 0 - 3.
RWORD0
0: No error
1: Error
66 Warning status
Not used with the IL Series.
RWORD0
67 System reserved
68
Judgment value
property
This property is output by assigning
sensor amplifiers (ID 01 to ID 05) bits
0 - 14.
The output occurs when the measured
value is nonnumeric: "over," "under,"
or "invalid."
RWORD0
0: Normally mea-
sured value
1: "over," "under," or
"invalid (-----)"