3-2 I/O Communication
3-15
3
Communicating with the IL Series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (IL) -
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 5-output modes including extended
modes.
The following describes how the DeviceNet master unit communicates with the DL-
DN1 (slave unit) using I/O communication (polling).
"Reading an output from a sensor amplifier" (page 3-15)
"Entering an external input into a sensor amplifier" (page 3-16)
"Reading comparator values (P.V. values) from sensor amplifiers" (page 3-17)
"Changing the BANK number of sensor amplifiers" (page 3-18)
"Rewriting a setting value of a sensor amplifier" (page 3-19)
For the communication methods using explicit messaging, see "Explicit
Messaging" (page 3-20).
Reading an output from a sensor amplifier
Available outputs: HIGH, LOW, GO, and alarm output
Device assignments: "Output" (page 3-8)
This example reads the HIGH output from the sensor amplifier of ID01.
It assumes that the operating mode assigned to the device is 3-output mode.
(1)The output from the sensor amplifier is brought into the IN area by I/O
communication.
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit0
Bit 15 Bit 14 ... Bit 9 Bit 8
n+11
Setting-value rewrite error
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+12
HIGH setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+13
LOW setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+14
Shift target value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+15
Analog output - upper limit
value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+16
Analog output - lower limit
value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
Communication Methods
PLC
Output of sensor amplifier
IN area [n+1]Bit0
Sensor amplifier
(1)
Output
HIGH output of ID 01
1
0
ON
OFF