User guide

3-2 I/O Communication
3-14
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (IL) -
3
Communicating with the IL Series
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 3-output modes including extended
modes.
5-output mode
OUT area
m: The first device number assigned to the DL-DN1
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
n+7
Setting-value rewrite error
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+8
HIGH setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+9
LOW setting value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+10
Shift target value (BANK 0)
rewrite complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+5
Request to rewrite HIGH
setting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+6 to 7
HIGH setting value (BANK 0)
HIGH setting value to be rewritten
(4-byte signed integer)
m+8
Request to rewrite LOW
setting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+9 to 10
LOW setting value (BANK 0)
LOW setting value to be rewritten
(4-byte signed integer)
m+11
Request to rewrite shift
target value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+12 to 13
Shift target value (BANK 0)
Shift target value to be rewritten
(4-byte signed integer)
m+14
Analog output - upper limit
value
(BANK 0)
rewrite request
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+15 to 16
Analog output - upper limit
value (BANK 0)
HIGH setting value to be rewritten
(4-byte signed integer)
m+17
Analog output - lower limit
value (BANK 0)
rewrite request
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+18 to 19
Analog output - lower limit
value (BANK 0)
LOW setting value to be rewritten
(4-byte signed integer)