3-2 I/O Communication
3-13
3
Communicating with the IL Series
- DeviceNet Compatible Network Unit DL-DN1 Userโs Manual (IL) -
๎ 5-output mode
OUT area
m: The first device number assigned to the DL-DN1
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 5-output modes including extended
modes.
Rewrite setting value
Sensor amplifier ID numbers 01 to 08 are assigned to bits 0 to 7, respectively.
For details of communication methods, see "Rewriting a setting value of a sensor
amplifier" (page 3-19).
๎ 3-output mode
OUT area
m: The first device number assigned to the DL-DN1
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+5 Request to change BANK
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+6 Select BANK number
Specifies a new BANK number
(2-byte unsigned integer; range: 0-3).
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
n+11 BANK change complete
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
n+12 BANK change error
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
Device 
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+3
Request to rewrite HIGH 
setting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+4 to 5
HIGH setting value (BANK 0)
HIGH setting value to be rewritten 
(4-byte signed integer)
m+6
Request to rewrite LOW 
setting value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+7 to 8
LOW setting value (BANK 0)
LOW setting value to be rewritten 
(4-byte signed integer)
m+9
Request to rewrite shift 
target value (BANK 0)
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+10 to 11
Shift target value (BANK 0)
Shift target value to be rewritten 
(4-byte signed integer)