User guide
2-1 Installation and Connection to Sensor Amplifiers
2-6
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (IL) -
2
Connection and Configuration
● Connecting to sensor amplifiers (panel mounting type)
1
Connect the optional expansion cable (OP-35361) between the sensor
amplifier and the DeviceNet compatible communication unit, DL-DN1.
2
Remove the sensor amplifier connector (for DIN rail mounting type) from
the DeviceNet compatible communication unit, DL-DN1, using pliers. In its
place, attach the expansion connector sticker supplied with the DL-DN1.
•  Turn off the power and connect the expansion cable securely. If 
the cable is not correctly connected, the DL-DN1 may be 
damaged when the power is turned on.
•  Do not attach or detach the cable with the power on, as this may 
damage the DL-DN1.
Expansion cable (300 mm long)
Peel off the protective sticker.
NOTICE
Sensor amplifier connector
(for DIN rail mounting type)
Expansion connector sticker