User guide

1-2
1
Before Using
- DeviceNet Compatible Network Unit DL-DN1 Userโ€™s Manual (IL) -
1-1
DL-DN1 Overview
The DL-DN1 operates as a slave unit of DeviceNet communication. Using DeviceNet
communications, the sensor amplifiers and other units connected to the DL-DN1 can
transmit their ON/OFF control signals and current values as communication data to a
PLC or other equipment.
The DL-DN1 supports DeviceNet I/O communication (polling) and explicit messaging.
I/O polling enables data communication without the need of a ladder program. Explicit
messaging allows for reading/writing sensor amplifier parameters and issuing motion
commands to the sensor amplifiers.
๎‚„ System configuration example
๎‚„ Number of Connectable Sensor Amplifiers
The DL-DN1 can connect to multiple sensor amplifiers (a single main unit and multiple
expansion units) which support D-Bus. "D-bus" is the name of KEYENCE's wiring-
saving system for sensor amplifiers.
Different types of sensor amplifiers with D-bus supp
or
t can be connected to a single
DL-DN1 unit.
How many and what types of sensor amplifiers can be connected depends on the
sensor amplifiers or units to be connected. Please inquire for details.
Overview
D-bus compatible sensor amplifier
PLC or other host device
(DeviceNet master unit)
DL-DN1 (This unit)
DeviceNet slave uni
t
KV-DN20
MS
NS
ON
TERM.
Types and Number of Connectable Sensor Amplifiers
Name Amplifier form Main unit
Expansion
unit
Maximum number of
connectable units
IL Series
DIN rail
mounting type
IL-1000 IL-1050
8
(1 main unit, 7 expansion units)
Panel
mounting type
IL-1500 IL-1550
8
(1 main unit, 7 expansion units)