Instruction Manual
3-3 Explicit Messaging
3-25
- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
3
Communicating with the IB Series
 •  When writing data of DINT type
Response format
 •  When normal (for writing response data of WORD, UINT, or DINT type)
 •  When abnormal
The following formats are used to activate the key lock on all sensor amplifiers
connected to the DL-DN1.
Command format
Service data
 Destination 
node 
address 
 Service 
Code 
 Attribute ID 
 **h 10h 0067h ****h **h ********h 
 Class ID 
 Instance ID 
 Service data 
 Data to be written 
 Specifi es the parameter to 
be written. 
Responder  
node address  
 Se rv ice Code  
 0002h  **h   90h   0000h  
 Response data 
 Number of receiv ed b ytes  
Responder  
node address 
 Se rv ice Code  
 0002h  **h   94h   FF**h 
 Response data 
(Error code) 
 Number of receiv ed b ytes  
Locking Sensor Amplifiers
Service data Action Description
0000h Deactivate key lock Deactivates key lock.
0001h Activate key lock Activates key lock.
Destination 
node address 
 Service 
Code 
 **h 4Ch 0067h 0000h (See below) 
 Class ID 
 Instance ID   Service data 