3-3 Explicit Messaging
3-23
- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
3
Communicating with the IB Series
Response format
 •  When normal
 •  When abnormal
Reading settings or status
Available settings and status: See "Common command parameter list" (page 3-
26) and "Setting/status command parameters" (page 3-30).
Command format
Service data need not be sent.
Response format
 •  When normal (for reading response data of WORD or UINT type)
 •  When normal (for reading response data of DINT type)
 •  When normal (for reading response data of STRING (16-byte) type)
Responder  
node address 
 Se rv ice Code  
 0002h  **h   CBh   0000h  
 Response data  Number of receiv ed b ytes  
Responder  
node address 
 Se rv ice Code  
 0002h  **h   94h   FF**h 
 Response data 
(Error code) 
 Number of receiv ed b ytes  
Reading/Writing Settings or Status of a Sensor Amplifier
Destination 
node address 
 Service 
Code 
 Attribute ID 
 **h 0Eh 0067h ****h **h 
 Specifi es the parameter to be read. 
 Class ID 
 Instance ID 
Responder  
node address  
 Se rv ice Code  
 0002h  **h   8Eh   ****h  
 Response data 
 Number of receiv ed b ytes  
Responder  
node address  
 Se rv ice Code  
 0004h  **h   8Eh   ********h  
 Response data  Number of receiv ed b ytes  
Responder 
node address
 Service Code 
 0010h **h 8Eh ********************************h 
 Response data
Number of received bytes  