3-3 Explicit Messaging
3-20
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -
3
Communicating with the FD-MH series
 Response format
 •  When normal
 •  When abnormal
Reading settings or status
Available settings and status: See  "Common Command Parameter List" (page
3-23) and  "Setting/status command parameters" (page 3-25).
 Command format
Service data need not be sent.
 Response format
 •  When normal (for reading response data of WORD or UINT type)
 •  When normal (for reading response data of DINT type)
 •  When normal (for reading response data of STRING (16-byte) type)
 •  When abnormal
Responder 
node address
 Service Code 
 0004h **h CBh 0000h 
 Response data  Number of received bytes  
Responder 
node address
 Service Code 
 0004h **h 94h FF**h 
 Response data 
(Error code) 
 Number of received bytes  
Reading/Writing Settings or Status of a Sensor Amplifier
Destination 
node address 
 Service 
Code 
 Attribute ID 
 **h 0Eh 0067h ****h **h 
 Specifi es the parameter to be read. 
 Class ID 
 Instance ID 
Responder 
node address 
 Service Code 
 0004h **h 8Eh ****h 
 Response data 
 Number of received bytes  
Responder 
node address 
 Service Code 
 0006h **h 8Eh ********h 
 Response data  Number of received bytes  
Responder 
node address
 Service Code 
 0010h **h 8Eh ********************************h 
 Response data
Number of received bytes  
Responder 
node address
 Service Code 
 0004h **h 94h FF**h 
 Response data 
(Error code) 
 Number of received bytes  